Direct answer
A technical specification is a document that defines what an industrial piece of equipment, material, or service must be and do, with requirements that are measurable and verifiable. It states scope, operating conditions, performance, standards, documentation, and acceptance tests, so any bidder can quote and any buyer can verify delivery.
Institutional content: Authomathika
Published:
A purchase order that says "a pump that fits our process" invites disputes. A technical specification removes that ambiguity by turning a need into requirements that a supplier can price and a buyer can check. This guide defines the document, shows its structure, and explains how to write requirements that hold up at acceptance.
What is a technical specification?
A technical specification is a document that describes the characteristics, performance, and conditions that equipment, material, or a service must meet to be accepted. It is written by the buyer or its engineering team and becomes part of the contract.
A good specification has three properties:
- Complete enough to quote: two bidders reading it should price the same scope.
- Verifiable: every requirement can be confirmed by measurement, inspection, test, or document review.
- Traceable: each requirement connects to a process need, a standard, or a site condition.
It applies to equipment such as a control valve or medium voltage switchgear, and also to services such as assembly, commissioning, or maintenance shutdowns.
What is the difference between a technical and a functional specification?
A functional specification describes what the system must achieve, while a technical specification describes how it must be built or what it must be made of. The first states the result, the second states the means.
| Aspect | Functional specification | Technical specification |
|---|---|---|
| Focus | Required outcome and behavior | Construction, materials, ratings, interfaces |
| Typical content | Process duty, operating modes, availability goals | Dimensions, electrical ratings, protection degree, standards |
| Supplier freedom | High, the supplier chooses the solution | Low, the buyer restricts the solution |
| Risk | Different bids are hard to compare | Over-restriction can block better solutions |
| Best used when | You trust the supplier's design | You must match an existing plant or standard |
In practice, most industrial documents mix both. State the function first, then restrict the technical choices only where the plant needs it, for example to keep spare parts, protocols, or panel layouts consistent with what you already operate.
Which sections should the document have?
A specification should have the sections below, in an order the reader can follow without jumping between pages. Adapt the list to the item being bought.
- Purpose and scope: what is included, what is excluded, and where the supply ends.
- Definitions and references: terms, abbreviations, and the documents the specification depends on.
- Site and operating conditions: ambient temperature range, altitude, humidity, corrosive atmosphere, area classification, utilities available.
- Process or functional requirements: duty, capacity, ranges, operating modes.
- Technical requirements: materials, ratings, enclosure protection, interfaces, communication protocols, signals.
- Applicable standards: the codes the item must comply with.
- Inspection and testing: factory tests, site tests, witness points, acceptance criteria.
- Documentation: datasheets, drawings, manuals, test reports, as-built records.
- Packaging, delivery, and warranty: transport conditions, spare parts, support after delivery.
- Deviations: how a bidder must declare any point it does not meet.
The scope and documentation sections connect directly to contracting. For the paperwork to ask for, see documents to require when contracting industrial projects.
How do you write measurable and testable requirements?
Write each requirement as one statement with a subject, a verb, a measurable value or condition, and a method of verification. If you cannot say how it will be checked, it is not yet a requirement.
Compare:
- Weak: "The panel must be robust and suitable for the environment."
- Strong: "The panel enclosure must have the ingress protection degree defined in the datasheet for the installation site, verified by the type test report and visual inspection at the factory."
Rules that keep requirements testable:
- One requirement per sentence. Compound sentences hide partial failures.
- Use "shall" for mandatory items and "should" for preferences, and keep that convention throughout.
- Give units and tolerances, and state the reference conditions for each value.
- Avoid vague words: "adequate", "high quality", "as needed", "state of the art".
- Link each requirement to a verification method: inspection, measurement, test, or document review.
- Put numbers in datasheets, not scattered through the text, so they are easy to update and compare.
Which standards should you cite and how?
Cite a standard when it is the recognized reference for the subject, by its full designation, and state that the edition in force applies unless you name another. Do not copy clauses into the specification; reference the standard and list only the points you need to emphasize or restrict.
Examples of the kind of references that appear in industrial electrical work include NR 10, ABNT NBR 5410, ABNT NBR 14039, and the IEC 61439 series for low voltage assemblies. For machines, NR 12 is the usual Brazilian reference. Your own project, jurisdiction, and equipment type decide which ones apply.
Good practice when referencing:
- Name the standard and the edition rule in one place, in the references section.
- Say which party verifies compliance and with what evidence, such as a test report.
- Define an order of precedence when documents conflict: contract, then specification, then datasheet, then standards.
- Ask the bidder to list every deviation from the cited standards.
Which mistakes should you avoid when writing?
The most common mistakes are vague wording, missing interfaces, and acceptance criteria that appear only after the order. Each one shifts risk to the buyer at the worst moment.
| Mistake | Consequence | Fix |
|---|---|---|
| Vague adjectives instead of values | Bids cannot be compared | State units, ranges, and tolerances |
| Unclear scope limits | Disputes over who supplies what | Define the supply boundary and the interfaces |
| Citing a standard without edition rule | Disagreement about which version applies | State that the edition in force applies, or name it |
| Copying an old specification unchanged | Obsolete requirements and contradictions | Review against current site conditions |
| No acceptance tests | No objective way to reject nonconforming items | Define tests, witness points, and criteria |
| Over-specifying the design | Blocks better or cheaper solutions | Specify function, restrict only where needed |
| Missing documentation list | Plant cannot maintain what it received | List every deliverable and its format |
Before issuing, have operations, maintenance, and procurement read the draft. Each group finds different gaps. A specification is often paired with a terms of reference for the service side and a descriptive memorandum for the solution side.
As an engineering integrator, Authomathika works across electrical, automation, and EPC engineering scopes, where a clear specification defines interfaces between disciplines. Scope and budget are assessed case by case, and you can start through the quote request page.