Skip to content

Oil and gas

What Is a Hazardous Area? Zones 0, 1 and 2 Explained

Learn what a hazardous area classification is, how gas, vapor and dust zones 0, 1 and 2 differ, and how to read a classification in oil and gas facilities.

Direct answer

A hazardous area is a location where a flammable gas, vapor, mist or dust may be present in quantities that require special precautions. Classification divides it into zones by how likely and how long an explosive atmosphere exists: Zone 0 continuous, Zone 1 occasional, Zone 2 unlikely and brief. Authomathika works with these drawings in electrical and automation projects.

Institutional content: Authomathika

Published:

Oil and gas facilities handle flammable liquids, gases and vapors every day. Wherever those substances can escape and mix with air, the site needs a map of where an explosion could occur. That map is the hazardous area classification, and reading it correctly is the first step before any decision about electrical work, instrumentation or maintenance.

What is a hazardous area?

A hazardous area is a location where an explosive atmosphere may form in quantities large enough to demand special precautions for equipment and work. An explosive atmosphere is a mixture of air with flammable gas, vapor, mist or dust that can ignite and propagate combustion after an ignition source appears. For a deeper look at the mixture itself, see explosive atmosphere: what it is, types and conditions.

Classification does not say a place is dangerous all the time. It describes how likely a flammable atmosphere is, and for how long it would persist, so that the same criteria can be applied across the whole plant.

What are Zones 0, 1 and 2 and how do they differ?

Zones 0, 1 and 2 are the gas and vapor zones, and they differ by how often and for how long an explosive atmosphere is present. The lower the number, the more frequent the presence.

ZoneExplosive gas atmosphere is...Typical idea
Zone 0Present continuously or for long periodsInside a vessel or tank headspace holding flammable liquid
Zone 1Likely to occur occasionally in normal operationAround a vent, a sampling point or a seal that may release
Zone 2Not likely in normal operation, and brief if it occursAround flanges and connections that leak only on failure

Dust has its own zones, numbered 20, 21 and 22 on the same logic: continuous, occasional and unlikely. Dust matters less in a typical oil and gas process area, but it appears in handling of solids such as coke, catalyst or sulfur.

The numbering follows the IEC approach used by many countries. Some regions, including North America, also use a Class and Division system. Check which scheme your project and local regulation adopt, and consult the current edition of the applicable standard.

How is an area classified in practice?

An area is classified by identifying every source of release, judging how often and how much it releases, and then considering ventilation to define the extent of each zone. The work is done by a qualified team and recorded in a formal study.

  1. List the flammable substances and their properties, such as flash point and whether they behave as gas, vapor or mist.
  2. Identify sources of release: vents, pump seals, valves, flanges, sample points, loading arms, open drains.
  3. Grade each release as continuous, primary (expected in normal operation) or secondary (only on failure).
  4. Assess ventilation: open air or enclosed, natural or forced, and how reliable it is.
  5. Define the zone type and its extent around each source, in distance and in elevation.
  6. Record the result on drawings and in a data sheet.

The how-to detail of this method is covered in hazardous area classification: how it is done.

Where do hazardous areas appear in oil and gas?

Hazardous areas appear wherever flammable hydrocarbons are stored, processed, transferred or vented. Common locations include:

  • Wellheads, separators and process modules
  • Compressor and pump areas handling hydrocarbons
  • Storage tanks and their dikes, including fuel tank farms
  • Loading and unloading bays for trucks, rail and ships
  • Flare, vent and drain systems
  • Laboratories and sample stations
  • Battery rooms or analyzer shelters, when gas can enter

The same plant usually mixes all three zones. A tank may have Zone 0 inside, Zone 1 around its vent and Zone 2 across the surrounding area.

What is in a hazardous area classification project?

A classification project is a set of documents that tells everyone what zone applies where and why. A complete package usually contains:

DocumentWhat it shows
Classification study or reportMethod, substances, sources of release and assumptions
Classification drawingsPlan and elevation views with zone boundaries and extents
Data sheets or source scheduleEach release source, its grade, ventilation and resulting zone
Substance dataGas group and temperature class of the flammable materials
Revision recordChanges after modifications to the plant

These documents are the input for equipment selection, but choosing equipment is a separate decision and is not covered here. Classification must be revised whenever the process, the layout or the substances change.

Authomathika, an engineering integrator of electrical systems, automation and industrial assembly, deals with this information in its electrical and automation scopes, where the classification drawings define the starting conditions for the work.

What common questions come up when reading a classification?

Most doubts come from reading a drawing without its context. Three points clear up many of them: a zone is defined by a release source and not by a plant area as a whole, the extent shown is a boundary and not a guarantee of safety outside it, and an unclassified area is not automatically safe for any activity. For the rules that govern work in these areas, see working in hazardous areas: general requirements.

Frequently asked questions

What is the difference between a hazardous area and an explosive atmosphere?
An explosive atmosphere is the actual flammable mixture with air. A hazardous area is the location where such a mixture may form, and it is classified into zones by how likely that mixture is.
Is Zone 0 more dangerous than Zone 2?
Zone 0 has an explosive atmosphere more often and for longer, so the probability of the mixture being present is higher. Zone 2 is where it is unlikely and, if it occurs, short lived.
Who is responsible for classifying an area?
The plant owner is responsible for having the area classified, usually through a qualified team that combines process, safety and electrical knowledge. Consult the current edition of the applicable standard and local regulation.
Do dust and gas use the same zones?
They follow the same logic but use different numbers. Gas and vapor use Zones 0, 1 and 2, while combustible dust uses Zones 20, 21 and 22.
How often must a classification be reviewed?
It must be reviewed whenever the process, the layout, the substances or the ventilation change. Many plants also schedule periodic reviews, defined by their own procedures and applicable rules.

Send your scope and receive a technical assessment from the Authomathika team.

Discuss your project ↗
What Is a Hazardous Area? Zones 0, 1 and 2 Explained | Authomathika