Skip to content

Oil and gas

Oil and Gas Electrical and Automation: Sector Guide

Oil and gas electrical and automation systems explained: typical facility areas, what is electrified and automated, hazardous area demands, and how to plan.

Direct answer

Oil and gas electrical and automation systems power, control and protect production, processing, transfer, storage and metering areas. They combine switchgear, motor control, PLC and DCS control, instrumentation and safety systems, built for hazardous areas and continuous operation. Authomathika integrates electrical, automation and electromechanical assembly for industrial plants.

Institutional content: Authomathika

Published:

Oil, gas and fuel facilities share a common challenge: flammable products handled continuously, with little tolerance for unplanned stops. Electrical and automation systems sit at the center of that challenge, because they supply energy, run the process and keep it within safe limits. This guide maps the typical areas of a facility and points to deeper guides for each one.

What are the typical areas of an oil, gas and fuel facility?

A facility is usually organized into production or receiving, processing, transfer, storage, metering and utilities, plus the buildings that house power and control. The exact mix depends on whether the site is an upstream field, a processing plant, a refinery, a terminal or a fuel distribution base.

  • Receiving and transfer: pipelines, pump stations, loading and unloading points.
  • Processing: separation, treatment, compression and conversion units, depending on the product.
  • Storage: tank farms and their pumping and piping manifolds.
  • Metering: measurement points where product changes hands or is reconciled.
  • Utilities: power distribution, instrument air, water, firefighting and flare or vent systems.
  • Buildings: substations, electrical rooms and control rooms.

What is electrified and automated in each area?

Each area has its own mix of loads, instruments and control logic, but the building blocks repeat: medium and low voltage distribution, motor control, field instrumentation, controllers and supervision.

AreaElectricalAutomation
Pump and transfer stationsMotor feeders, motor control centers, drives or soft startersPump sequencing, valve control, flow and pressure monitoring
Processing unitsDistribution boards, motor control, heat tracing, lightingPLC or DCS loops, interlocks, alarms, shutdown logic
Tank farmsPower for pumps, valves and field panelsLevel, temperature and valve control, transfer sequences
MeteringPower and signal conditioning for instrumentsFlow computers, data acquisition, reporting to supervision
UtilitiesSubstations, backup power, groundingMonitoring of power, air and water systems

For storage areas, see fuel tank farms and how they are automated. For measurement points, see fiscal metering of oil and natural gas.

What environment and operating particularities does the sector impose?

The main particularity is the presence of flammable gases and vapors, which turns large parts of the plant into classified areas. Equipment there must be selected, installed and maintained for the area classification defined in the project.

A hazardous area is a location where an explosive atmosphere may occur in quantities that require special precautions. Zones 0, 1 and 2 describe how often that atmosphere is expected. The guides on hazardous areas and zones 0, 1 and 2 and on explosive atmospheres explain the concepts in detail.

Other common conditions:

  • Outdoor exposure, corrosion, humidity and temperature swings, which affect enclosure, cable and instrument selection.
  • Continuous operation, which favors redundancy and maintainability.
  • Strong safety philosophy, with shutdown and alarm functions kept separate from basic process control where the project requires it.
  • Large distances between areas, which shape cabling, networks and communication.

How are shutdowns and expansions handled?

Shutdowns and expansions are planned around the limited window in which a unit can be stopped, so most of the work is done in preparation. The goal is to arrive at the stop with scope frozen, materials on site, teams defined and tests planned.

  1. Survey the existing installation, including drawings, loads, logic and interfaces.
  2. Define what can be built ahead of time while the plant runs and what requires the stop.
  3. Prepare materials, panels and cable pulls before the window opens.
  4. Plan commissioning and functional tests, including interlocks and alarms.
  5. Update documentation to the as built condition at the end.

For a related planning method, read how to prepare a maintenance shutdown.

Which disciplines must be integrated in the project?

Electrical, automation, instrumentation, mechanical assembly and civil work must be designed and executed against the same schedule and the same interface list. Gaps between disciplines are where rework usually appears.

InterfaceWhat must be agreed
Electrical and automationMotor control signals, drive communication, power for instruments
Automation and instrumentationSignal types, ranges, loop drawings, hazardous area protection
Electrical and mechanical assemblyCable routes, supports, equipment placement, access
Project and operationsOperating philosophy, alarms, shutdown logic, acceptance tests

Criteria for accepting the integration:

  • Interface list closed and signed off by all disciplines.
  • Documentation consistent across drawings, lists and logic.
  • Factory and site tests defined before execution.
  • Clear responsibility for commissioning each system.

How does Authomathika work with electrical, automation and assembly?

Authomathika is an engineering integrator of electrical systems, automation and industrial assembly, founded in 1999 and based in Sertãozinho, São Paulo, Brazil. It covers electrical, automation and electromechanical assembly, and can also deliver complete EPC engineering projects.

Its published track record in automation includes 49 Greenfield plants and 144 Brownfield plants, with 101.512 DCS points and 278.699 PLC points (380.211 total). Services and products are evaluated by scope and budget, and there is no standard price list or lead time. Check each project page to distinguish Authomathika's participation from the total capacity of the installation.

Frequently asked questions

Is oil and gas automation different from other industrial automation?
The building blocks are the same: PLC, DCS, instrumentation and supervision. The difference is the weight of safety functions, hazardous area requirements and the need for continuous operation.
Do all areas of an oil and gas facility need explosion protected equipment?
No. Only areas classified as hazardous in the project need it. Area classification defines where, and equipment must match the zone and the product handled.
What should I gather before asking for a proposal?
Gather the area classification, single line diagrams, load lists, instrument lists, existing control system details and the shutdown window. Clear scope reduces assumptions in the proposal.
Can electrical and automation be contracted separately?
Yes, but interfaces then need strong coordination. Contracting them together under one integrator or an EPC arrangement reduces gaps, though the best option depends on project size and your internal team.
Where can I send a request for a proposal?
Use the contact page, call (16) 3513-4000 or write to comercial@authomathika.com.br.